Karl Deutsch ESV / MSV demagnetising coils
Applications
For demagnetising parts outside DEUTROFLUX benches – after magnetic particle testing, before machining or assembly. With a conveyor or inclined chute – for an automated continuous process.
Key features
- Field strength at the coil centre > 20 kA/m (> 250 Oe)
- Continuous-duty design, 400 V / 50 Hz
- Six standard sizes, other sizes and rectangular shapes on request
- MSV version in a potted water-resistant housing
- Accessories: conveyors, inclined stands, low-frequency generators for special cases
Models
ESV 100 S (3601.1); ESV 150 S (3602.1); ESV 200 S (3603.1); ESV 300 S (3604.1); ESV 400 S (3605.1); ESV 500 S (3606.1); MSV versions in a water-resistant housing
Technical data
- Inner opening: 100 × 100 … 500 × 500 mm (type number = side length in mm)
- Field strength: > 20 kA/m; penetration depth of the alternating field ~2 mm
- Power supply: 400 V / 50 Hz
What we offer
- Selection of the instrument and configuration for your task, together with the manufacturer
- Trial measurements of your samples in the manufacturer’s laboratory
- Training, calibration and service organised through the manufacturer
Technical data according to the manufacturer: karldeutsch.de
You might also be interested in
Karl Deutsch DEUTROPULS hand yokes – mobile magnetic particle testing
For mobile magnetic particle testing of ferromagnetic parts and welds in the workshop, on construction sites or during assembly, including under harsh conditions.
Karl Deutsch DEUTROPULS SW – portable high-current generators for MT
For mobile MT inspection of large structures, castings and forgings using the current flow method when a yoke is not sufficient.
Karl Deutsch FLUXA – magnetic particle testing media
For all MT tasks – from series fluorescent inspection on stationary DEUTROFLUX lines to single-part black-and-white inspection in the field where darkening is not possible.
Karl Deutsch DEUTROMETER 3873 – magnetic field strength and UV light meter
For checking the tangential field strength during magnetisation and the residual field after demagnetisation according to EN ISO 9934-3 and EN ISO 17638; the UNIVERSAL and LIGHT versions additionally measure UV irradiance and white-light illuminance according to EN ISO 3059 – required to verify the conditions for fluorescent MT and PT inspection.
Karl Deutsch reference magnet and zero-field chamber – DEUTROMETER accessories
For periodic checking and zeroing of the DEUTROMETER and its probes in line with quality system requirements.
Karl Deutsch UV-LED large-area lamp 3846 – stationary UV lamp for MT and PT
For stationary use in MT and PT inspection booths and lines.
Karl Deutsch UV-LED hand lamp 3817.101 – portable UV lamp for MT and PT (new)
For mobile fluorescent MT and PT inspection on the shop floor and in the field – with two battery packs and a case.