{"id":3560,"date":"2020-12-20T01:18:10","date_gmt":"2020-12-19T23:18:10","guid":{"rendered":"https:\/\/m-technologijos.lt\/produktai\/qness-qatm-model-chd-master-2\/"},"modified":"2023-10-17T11:04:25","modified_gmt":"2023-10-17T08:04:25","slug":"qness-qatm-model-chd-master-2","status":"publish","type":"products","link":"https:\/\/m-technologijos.lt\/en\/iranga\/hardness-testing\/qness-qatm-model-chd-master-2\/","title":{"rendered":"QATM Model CHD Master \u2013 Fully Automatic, Economically, Up-To-Date"},"content":{"rendered":"<h2>Test Methods and Force Application<\/h2>\n<p>&nbsp;<\/p>\n<div class=\"summary entry-summary\">\n<div class=\"woocommerce-product-details__short-description\">\n<h4 class=\"western\">Q10 CHD Master<\/h4>\n<p class=\"western\"><strong><img decoding=\"async\" src=\"https:\/\/www.qatm.com\/images\/ab20ff8cc6e3d9de539ae8ddefed9793\/870x\/max\/alpha.webp\" \/><\/strong><\/p>\n<h4 class=\"western\">Q30 CHD Master<\/h4>\n<p class=\"western\"><strong><img decoding=\"async\" src=\"https:\/\/www.qatm.com\/images\/de4b0dd8fee196bd9b4ef099bb6130f1\/870x\/max\/alpha.webp\" \/><\/strong><\/p>\n<h4 class=\"western\">Q60\u00a0CHD Master<\/h4>\n<p class=\"western\"><strong><img decoding=\"async\" src=\"https:\/\/www.qatm.com\/images\/d04f033d72418507221ddf2bebacee93\/870x\/max\/alpha.webp\" \/><\/strong><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Convincing benefits<\/h2>\n<div class=\"grid-100 tablet-grid-100\">\n<h4 class=\"text-left s-small w-bold t-upper\">Ready to test<\/h4>\n<\/div>\n<div class=\"grid-100 tablet-grid-100\">\n<p>Vickers indenter and 3 lenses included in the basic package -no restrictions with test methods; all test load steps available and immediately useable.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"grid-100 tablet-grid-100\">\n<h4 class=\"text-left s-small w-bold t-upper\">Fully automatic test sequence<\/h4>\n<\/div>\n<div class=\"grid-100 tablet-grid-100\">\n<p>With electronic load application and an enclosed circuit.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<h4 class=\"grid-100 tablet-grid-100\">6-fold tool-change turret<\/h4>\n<div class=\"grid-100 tablet-grid-100\">\n<div class=\"grid-100 tablet-grid-100\">\n<p>The 6-fold tool-change turret is standard and offers plenty ofspace for various test methods.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"grid-100 tablet-grid-100\">\n<h4 class=\"text-left s-small w-bold t-upper\">Optimum stop<\/h4>\n<\/div>\n<div class=\"grid-100 tablet-grid-100\">\n<p>Time-saving mode completes test series as soon as lower hardness limit has been undercut.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>A simple start to fully-automated hardness testing<\/h2>\n<div class=\"grid-100 tablet-grid-100\">\n<h4 class=\"text-left s-small w-bold t-upper\">Largest test space<\/h4>\n<\/div>\n<div class=\"grid-100 tablet-grid-100\">\n<p>The sophisticated construction in anodized aluminium offers a large and well-arranged test space. The fully automatic XY-slide with a high- precision incremental measurement system can be equipped with an 1-fold sample holder. Beyond that, customer specific magazines can be managed and created in the software.<\/p>\n<h4><\/h4>\n<\/div>\n<h4>Template function<\/h4>\n<div class=\"grid-100 tablet-grid-100\">\n<ul>\n<li>Types of measurement: CHD, NHD, SHD, row measurement, rapid single measurements<\/li>\n<li>Template function ideal for repeat tests \/ components<\/li>\n<li>Pull test series into the desired position<\/li>\n<li>The row starting point is automatically determined by the Auto-Snap function<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<h4>Protocol and data presentation<\/h4>\n<div class=\"grid-100 tablet-grid-100\">\n<p>Wide range of structuration options for stored test item data. Adaptable content for export files and protocol content.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<h4>Modular expandable with sample image camera<\/h4>\n<div class=\"grid-100 tablet-grid-100\">\n<div class=\"grid-100 tablet-grid-100\">\n<p>Modular upgrade with sample image camera for the CHD Master possible at any time \u2013 as \u201cCHD MASTER +\u201d ready for new applications.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<h2>Software<\/h2>\n<h4>Revolutionary 3D concept<\/h4>\n<div class=\"text-image\">\n<div class=\"grid-100 tablet-grid-100\">\n<div class=\"grid-100 tablet-grid-100\">\n<p>Intuitive, clearly structured and professional: Qpix Control2 heralds a new generation of hardness testing software developed to guarantee maximum user-friendliness.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"text-image\">\n<div class=\"grid-100 tablet-grid-100\">\n<p>More Information about the Qpix Control2 Software on <a class=\"internal-link\" href=\"https:\/\/www.qatm.com\/products\/hardness-testing\/software\/qpix-control2\/\">Qness WEB page<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Technical Data<\/h2>\n<table style=\"height: 1026px;\" width=\"760\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" style=\"width: 350px;\" align=\"left\">Test force range<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">50 g \u2013 10 kg (0.49 \u2013 98.1 N)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Tool changer<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">6-fold, motorized<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Software<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\"><a href=\"https:\/\/www.qness.com\/products\/software\/qpix-control2\/function-features\/\">Qpix Control2<\/a><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Types of measurement<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">CHD, NHD, RHD, Single piece-, row measurement<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Test anvil \/ Cross slide<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">motorized<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Traverse path X\/Y\/Z<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">X 150 \/ Y 150 \/ Z 145 mm<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Weight of basic machine<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">px<\/p>\n<p class=\"western\" align=\"left\">58 kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Data interface<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">1x USB3.0: Interface PC hardness tester<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Repeatability X\/Y slide<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">+\/- 3.5 \u00b5m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Camera system<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">18 MP color camera<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Max. workpiece weight<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">50 kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Power supply<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">230~1\/N\/PE, 110~1\/N\/PE<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Max. power consumption<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">~200 W<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Accessories and Options<\/h2>\n<table style=\"height: 221px;\" width=\"761\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Included lenses and indenters<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">Lenses: 4x, 20x, 40x<br \/>\nDakkS- certified Vickers indenter<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"177\">\n<p class=\"western\" align=\"left\">Sample holder (option)<\/p>\n<\/td>\n<td width=\"457\">\n<p class=\"western\" align=\"left\">CHD Master: 1-fold (\u00d8 30 \/ 40 \/ 50 mm)<br \/>\nCHD Master+: 1-fold (\u00d8 30 \/ 40 \/ 50 mm), 4-fold (\u00d8 30 \/ 40 \/ 50 mm), 8-fold (\u00d8 30 \/ 40 mm)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#ffffff\" width=\"177\">\n<p class=\"western\" align=\"left\">Data connection plugins (option)<\/p>\n<\/td>\n<td bgcolor=\"#ffffff\" width=\"457\">\n<p class=\"western\" align=\"left\">QDAS, PCI, AMS, REMOTE<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Test Methods and Force Application &nbsp; Q10 CHD Master Q30&hellip;<\/p>\n","protected":false},"featured_media":2817,"template":"","meta":{"mt_image_url":"","footnotes":""},"categories":[112],"class_list":["post-3560","products","type-products","status-publish","has-post-thumbnail","hentry","category-hardness-testing"],"_links":{"self":[{"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/products\/3560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/products"}],"about":[{"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/types\/products"}],"version-history":[{"count":1,"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/products\/3560\/revisions"}],"predecessor-version":[{"id":3561,"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/products\/3560\/revisions\/3561"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/media\/2817"}],"wp:attachment":[{"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/media?parent=3560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/m-technologijos.lt\/en\/wp-json\/wp\/v2\/categories?post=3560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}